Load cell M105

Double bending beam load cell. Measuring element from Beryllium-Copper alloy. 3000 divisions O.I.M.L. R60 class C. Protected against humidity up to 95 % (N.C.). 'Single point' load cell. High accuracy with off-center loads. 6 wire (sense) electrical connection. Integrated on-center overload protection (must be adjusted with 150 % Ln)

Technical documentation

Nominal capacities 2 - 3 - 5 kg
Accuracy class 3000 n. OIML
Minimum dead load 0 % Ln
Service load 150 % Ln
Safe load limit 200 % Ln
Total error <±0.017 % Sn
Repeatability error <±0.01 %Sn
Temperature effect on zero <±0.01 %Sn/5K
Temperature effect on sensitivity <±0.006 %Sn/5K
Creep error (30 minutes) <±0.016 %Sn/5K
Temperature compensation -10 až +40 °C
Temperature limits -20 až +50 °C
Nominal sensitivity (Sn) 2±10% mV/V
Nominal input voltage 10 V
Max. input voltage 15 V
Input impedance 400±20 Ohm
Output impedance 350±3 Ohm
No load output <±2 %Sn
Insulation resistance >5000 MOhm
Max.deflection (at Ln) 0.4 - 0.5 mm