Load cell M650 ATEX

  • Tension-compression load cell
  • Measuring element from stainless steel
  • 3000 divisions O.I.M.L. R60 class C
  • Protected IP 68(DIN 40050)
  • Zone 0-1-2 (gas) and 20-21-22 (dust)

Technical documentation

Nominal capacities 250-500-1000-2000-5000-7500 kg
Accuracy class 3000 n. OIML
Minimum dead load 0 %Ln
Service load 150 %Ln
Safe load limit 200 %Ln
Total error < ± 0.017 %Sn
Repeatability error < ± 0.015 %Sn
Temperature effect on zero < ± 0.01 %Sn/5K
Temperature effect on sensitivity < ± 0.006 %Sn/5K
Creep error (30 minutes) < ± 0.016 %Sn/5K
Temperature compensation -10 to +40 ° C
Temperature limits -40 to +95 ° C
Nominal sensitivity (Sn) 2 ± 10% mV/V
Nominal input voltage 10 V
Max. input voltage 15 V
Input impedance 400 ± 20 Ohm
Output impedance 350 ± 3 Ohm
No load output < ± 2 %Sn
Insulation resistance > 5000 MOhm
Max.deflection (at Ln) <0.5 mm