Load cell M750 ATEX

Double shear load cell. Measuring element from stainless steel. 3000 divisions O.I.M.L. R60 class C Hermetic, protected IP 68 (DIN 40050). 6 wire (sense) electrical connection. Application: Tanks, silos and vehicle weighing systems with highly linear and low profile requirements.

  • Double shear load cell
  • Measuring element from stainless steel
  • 3000 divisions O.I.M.L. R60 class C
  • Hermetic, protected IP 68 (DIN 40050)
  • 6 wire (sense) electrical connection
  • Application: Tanks, silos and vehicle weighing systems with highly linear and low profile requirements.

Technical documentation

Nominal capacities 7,5-10-15-20-25-30 t
Accuracy class 3000 n. OIML
Minimum dead load 0 %Ln
Service load 150 %Ln
Safe load limit 200 %Ln
Total error < ± 0.017 %Sn
Repeatability error < ± 0.015 %Sn
Temperature effect on zero < ± 0.01 %Sn/5K
Temperature effect on sensitivity < ± 0.006 %Sn/5K
Creep error (30 minutes) < ± 0.016 %Sn/5K
Temperature compensation -10 až +40 ° C
Temperature limits -20 až +7 ° C
Nominal sensitivity (Sn) 2 ± 0.1% mV/V
Nominal input voltage 10 V
Max. input voltage 15 V
Input impedance 800 ± 25 Ohm
Output impedance 700 ± 3 Ohm
No load output < ± 2 %Sn
Insulation resistance > 5000 MOhm
Max.deflection (at Ln) 0.3 mm