Load cell M490

Double shear load cell with measuring element from alloy steel. Conditioned for service temperature up to 150°C.

  • Double shear load cell
  • Measuring element from alloy steel with nickel plated treatment
  • Service temperature up to 150°C
  • Protected IP 67 (DIN 40050)
  • Input cable connection through hermetic connector
  • Applications: Ladle turret and ladle ferry scales, scrap bucket, roller table, tundish cars, hopper and silos in high temperature environments for the metal industry.

Technical documentation

Nominal capacities 40-50-100-150-200 t
Accuracy class ±0,05 %
Minimum dead load 0 %Ln
Service load 150 %Ln
Safe load limit 180 %Ln
Total error < ± 0.05 %Sn
Repeatability error < ± 0.05 %Sn
Temperature effect on zero < ± 0.025 %Sn/5K
Temperature effect on sensitivity < ± 0.015 %Sn/5K
Creep error (30 minutes) < ± 0.05 %Sn/5K
Temperature compensation -10 až +100 ° C
Temperature limits -30 až +150 ° C
Nominal sensitivity (Sn) 2 ± 0.25% mV/V
Nominal input voltage 10 V
Max. input voltage 15 V
Input impedance 800 ± 30 Ohm
Output impedance 700 ± 3 Ohm
No load output < ± 2 %Sn
Insulation resistance > 5000 MOhm
Max.deflection (at Ln) 0.6 - 1 mm