Load cell M230

Double bending beam load cell. Measuring element from aluminium. 3000 divisions O.I.M.L. R60 class C. Protected IP 66 (EN 60529). Single point load cell. High accuracy with off-center loads.

  • Double bending beam load cell
  • Measuring element from aluminium
  • 3000 divisions O.I.M.L. R60 class C
  • Protected IP 66 (EN 60529)
  • Single point load cell. High accuracy with off-center loads
  • Aplications:
    • single point platform scales up to 400x400 mm
    • price computing scales, counting scales, etc.

Technical documentation

Nominal capacities 7,5-12-18-36 kg
Accuracy class 3000 n. OIML
Minimum dead load 0 %Ln
Service load 120 %Ln
Safe load limit 150 %Ln
Total error < ± 0.017 %Sn
Repeatability error < ± 0.01 %Sn
Temperature effect on zero < ± 0.01 %Sn/5K
Temperature effect on sensitivity < ± 0.006 %Sn/5K
Creep error (30 minutes) < ± 0.016 %Sn/5K
Temperature compensation -10 až +40 ° C
Temperature limits -20 až +70 ° C
Nominal sensitivity (Sn) 2,4 mV/V
Nominal input voltage 10 V
Max. input voltage 15 V
Input impedance 400 ± 20 Ohm
Output impedance 350 ± 3 Ohm
No load output < ± 2 %Sn
Insulation resistance > 5000 MOhm
Max.deflection (at Ln) 0.2 - 0.4 mm